Home > Buy Now > Respiratory Equipment > Ventilator > TKR-400(T) High-frequency Mutil-functional Ventilator
 


Ternary Anaesthesia & Respiration Equipment Co., Ltd.
 
icon My Products

line

icon Company Profile
icon Selling Leads

line

 
Contact us
Ternary Anaesthesia & Respiration Equipment Co., Ltd.
[China]
Address:
No.819 Aixi lake 4th Road eastern, Hi-tech Development Zone Nanchang Jiangxi 330096 China
Phone:
86-0791-8130927
Contact name:
Fish YUAN , sales agent
Inquire now










Ternary Anaesthesia & Respiration Equipment Co., Ltd.



 
My Products

TKR-400(T) High-frequency Mutil-functional Ventilator

Inquire now

TKR-400(T) High-frequency Mutil-functional Ventilator

Click to enlarge image

 Origin China
 Model Number TKR-400(T)

Feature: A. HFJV (High-frequency jet ventilation) with pressure support, which can supply a higher inspiratory pressure so that the patients can aspirate sufficient oxygen easily. B. Opening airway. The ventilation can be made with high frequency and little tidal volume and low airway pressure, which is beneficial to increase the blood oxygen density. C. Ventilation mode through nasal vestibule non-invasive which can avoid from tracheotomy and endotracheal tube so as to reduce patient's pain and the effectiveness of oxygen feeding is very good, the patient can talk, drink and eat, when ventilating. D. Continuous positive airway pressure with adjustable oxygen concentration plus effective humidifier can make the feature of CPAP better. E. Adopted digital display screen, which displays all parameters accurately and improves the performance and accuracy of the ventilator. F. The multi-functional humidifier adaptor can be connected with any type of humidifier by trachea intubation with national or international standard. G. The pressure humidifier has switch to manipulate the air volume and has the delicacy alarm with sound and light for no power or gas. Specifications: ??requency: 10~150 breaths/min ??/E ratio: 1 : 1~ 1 : 4 and inverse ratio Humidifying rate: No less than 15ml/h ??rocess Ventilation: T=10min, I/E=1: 1.5 ProI: ??(150): f(15)=7: 3 ProII: ??(15): f(150)=7: 3 ??IGH: 6 breaths/min ??larm: Alarm with light and sound for no power or no gas for 6 seconds. ??PAP: 0.1kPa~0.8Kpa ??EEP: 0.1kPa~0.5kPa ??aximum Oxygen Concentration: 85% ??larm for upper-limitation of airway pressure: Three conditions: 0.5KPa, 1.0Kpa, 2.0Kpa ??ressure Regulator Limit: 0. 3MPa ??entilation Mode: HFJV(High Frequency Jet Ventilation);CPAP(Continuous positive airway pressure);ProI and ProII ventilations; HFJV+SIGH, HFJV+PEEP and Manual ventilation.




Inquire now